8. Problems and solutions

ProblemReasonSolution
No element is activated.Circuit breaker on OFF position.Switch circuit breaker to ON.
No pump or heating is activated.Operating switch in OFF position.Change operating switch to ON.

FILTER

Low water flow during filtration.Obstructed or dirty filter.Wash filter. 
Filter pump is not activated.Filter pump faulty.Check pump / Change brushes.
Faulty or poorly connected contactor.Installer: Check connection wires. Change contactor.
Poorly regulated thermal magnetic breaker.Adjust thermal magnetic breaker according to motor consumption.
Faulty thermal magnetic breaker.Change thermal magnetic breaker.
Pump selector on stop.Change to manual or automatic.

WATER MASSAGE

Massage pump is not activated.Signal transmission cable disconnected.Conectar el tubito* / cable.
Air bulb in push button damaged.*Change bulb.*
Faulty pump.Check pump / Change brushes.
Faulty or poorly connected ontactor.Installer: Check connection cables. Change contactor.
Poorly regulated thermal magnetic breaker.Adjust thermal magnetic breaker according to motor consumption.
Faulty thermal magnetic breaker. Change thermal magnetic breaker.
General massage switch on OFF.Set switch to ON.
Low air flow in jets.
Water comes out the Venturi jet.
Closed and obstructed venturis.Open Venturis.
Eliminate obstructions
Incorrectly placed jet frontCheck jets

AIR MASSAGE

The massage pump is not activated.Signal transmission wire disconnected.Connect the cable.
Air bulb in push button damaged.*Change bulb.*
Faulty pump.Check the pump / Change brushes.
Faulty or poorly connected contactor.Installer: Check connection wires. Change contactor.
Badly regulated thermal magnetic breaker.Adjust thermal magnetic breaker according to motor consumption.
Faulty thermal magnetic breaker.Change thermal magnetic breaker.
General massage switch on OFF.Change switch position to ON.

HEAT EXCHANGER

The thermostat does not indicate the correct temperature.Poorly fitted temperature probe.Fit the probe properly into its housing.
Faulty temperature probe.Change the probe.
Temperature controller damaged.Change controller.


No hot water.
Heat exchanger badly wired / defective.
Check wiring resistance / 
Change Heat exchanger.
Contactor damaged or bad connection.Installer: Check wiring connection. Replace contactor.
Magneto – thermal damaged.Change magneto -thermal.
Exchanger switch OFF.Turn switch to ON.
Flow switch bad wired / damaged.Check wiring flow-switch /
Change flow switch.
Safety thermostat detect T>65ºC.Reset safety thermostat

* Only in the case of pneumatic push buttons.