| Problem | Reason | Solution |
| No element is activated. | Circuit breaker on OFF position. | Switch circuit breaker to ON. |
| No pump or heating is activated. | Operating switch in OFF position. | Change operating switch to ON. |
FILTER
| Low water flow during filtration. | Obstructed or dirty filter. | Wash filter. |
| Filter pump is not activated. | Filter pump faulty. | Check pump / Change brushes. |
| Faulty or poorly connected contactor. | Installer: Check connection wires. Change contactor. | |
| Poorly regulated thermal magnetic breaker. | Adjust thermal magnetic breaker according to motor consumption. | |
| Faulty thermal magnetic breaker. | Change thermal magnetic breaker. | |
| Pump selector on stop. | Change to manual or automatic. |
WATER MASSAGE
| Massage pump is not activated. | Signal transmission cable disconnected. | Conectar el tubito* / cable. |
| Air bulb in push button damaged.* | Change bulb.* | |
| Faulty pump. | Check pump / Change brushes. | |
| Faulty or poorly connected ontactor. | Installer: Check connection cables. Change contactor. | |
| Poorly regulated thermal magnetic breaker. | Adjust thermal magnetic breaker according to motor consumption. | |
| Faulty thermal magnetic breaker. | Change thermal magnetic breaker. | |
| General massage switch on OFF. | Set switch to ON. | |
| Low air flow in jets. Water comes out the Venturi jet. | Closed and obstructed venturis. | Open Venturis. Eliminate obstructions |
| Incorrectly placed jet front | Check jets |
AIR MASSAGE
| The massage pump is not activated. | Signal transmission wire disconnected. | Connect the cable. |
| Air bulb in push button damaged.* | Change bulb.* | |
| Faulty pump. | Check the pump / Change brushes. | |
| Faulty or poorly connected contactor. | Installer: Check connection wires. Change contactor. | |
| Badly regulated thermal magnetic breaker. | Adjust thermal magnetic breaker according to motor consumption. | |
| Faulty thermal magnetic breaker. | Change thermal magnetic breaker. | |
| General massage switch on OFF. | Change switch position to ON. |
HEAT EXCHANGER
| The thermostat does not indicate the correct temperature. | Poorly fitted temperature probe. | Fit the probe properly into its housing. |
| Faulty temperature probe. | Change the probe. | |
| Temperature controller damaged. | Change controller. | |
No hot water. | Heat exchanger badly wired / defective. | Check wiring resistance / Change Heat exchanger. |
| Contactor damaged or bad connection. | Installer: Check wiring connection. Replace contactor. | |
| Magneto – thermal damaged. | Change magneto -thermal. | |
| Exchanger switch OFF. | Turn switch to ON. | |
| Flow switch bad wired / damaged. | Check wiring flow-switch / Change flow switch. | |
| Safety thermostat detect T>65ºC. | Reset safety thermostat |