5.3. Configuration menus

TIME AND FILTRATION CYCLE SETTING 

When the system is in MANUAL mode, press for 3 seconds to start the Time and Filtration Cycle Menu.

  • The 1st parameter (T1) appears in the display.

Press up and down buttons  to set the hour (2 digits). 

Press  to confirm.

  • The 2nd parameter (T2) appears in the display. 

Press up and down buttons  to set the minutes (2digits). 

Press  to confirm.

  • The 3rd parameter (C1) appears in the display. 

Press up and down buttons  to set what time the filtration cycle starts (2 digits). Hourly only. 

Press  to confirm.

  • The 4th parameter (C2) appears in the display. 

Press up and down buttons  to set what time the filtration cycle ends (2 digits). Hourly only. 

Press  to confirm.

  • C1 and C2 fields refer to hours, not minutes.
  • If C1 = C2 the circulation pump is always running.
  • Press  or  or wait 10 seconds to exit Time and Filtration Cycle Setting Menu.

PUMPS MANUAL CONTROL MENU. FILTER BACK WASHING

  • The system can control up to 5 pumps: 1 filtration pump, 1 to 3 massage pumps, and 1 blower.
  • When the system is in MANUAL mode press  and the 1st parameter, PF (Filtration Pump), will be shown in the display. 

Pressing  the PF value turns to ON and pressing  the PF value turns to OFF.

  • Press  again and the 2nd parameter, BL Blower, will be shown in the display. 

Pressing  the BL value turns to ON and pressing  the BL value turns to OFF.

  • Press  again and the 3rd parameter, P1 (Massage pump 1), will be shown in the display. 

Pressing  the P1 value turns to ON and pressing  the P1 value turns to OFF.

  • Press again  and the 4th parameter, P2 (If installed, Massage pump 2), will be shown in the display. 

Pressing the P2 value turns to ON and pressing  the P2 value turns to OFF.

  • Press  again and the 5th parameter, P3 (If installed, Massage pump 3), will be shown in the display. 

Pressing the P3 value turns to ON and pressing  the P3 value turns to OFF.

  • Press  to exit MANUAL mode and the system will turn to AUTOMATIC mode.

To simplify the technical assistance and electronic management all systems have the same version of software. The System always shows 3 massage pumps that can be virtually operated even if they are not physically installed .

According to European safety regulations, the system will automatically activate the filtration pump when a massage or blower pump is in use.

Manual Pumps Activation

ParameterDescriptionValueDefault value
Involved Function
PFFiltration PumpON/OFFOFFFiltration / Backwashing
BLOn/Off BlowerON/OFFOFFAir massage
P1On/Off Pump 1ON/OFFOFFWater massage
P2On/Off Pump 2ON/OFFOFFWater massage
P3On/Off Pump 3ON/OFFOFFWater massage

DAILY WATER REPLACEMENT FUNCTION

Legislation requires that public use spas guarantee that a percentage of spa water is replaced daily. The replacement rate will depend on the legislation in force in each country.

This system opens the solenoid fill valve daily for a certain period of time (which can be set by the customer according to the diameter and pressure of the fill system).

The water replacement function takes into account the amount of time the solenoid fill valve is open for maintenance and/or auto-fill functions, subtracting this amount of time from that programmed by the customer.

The water replacement function will still run even if the circuit is filled to the surge tank’s maximum level.

Manual drainage is required should the circuit require draining due to excess water in the surge tank.

TEMPERATURE

  • Current Spa temperature is shown in the display when the system is in ON mode.

ON / STANDBY button  lights up.

  • Press or  once the programmed temperature (Set Point) is shown in the display.
  • Continue pressing  or  the programmed temperature (SP) will go up or down.
  • When the temperature will be in the desired value stop pressing. The system memorizes the value automatically.
  • Default spa temperature is 36ºC.
  • If the power supply is interrupted, the programmed temperature (Set Point) value returns to the last Set Point programmed.

Temperature program

ParameterDescriptionIntervalDefault valueInvolved Function
SPProgrammed temperature15-40 (ºC)36 (ºC)Heating
59-104 (ºF)97 (ºF)

Temperature unit can be changed in the UNITS AND MASSAGE SETTING MENU.

UNITS AND MASSAGE

  • When the system is in MANUAL mode Press  for 3 seconds and the system displays the UNITS AND MASSAGE SETTING MENU.
  • The 1st parameter, Un (Unit of temperature) will be shown in the display.

Pressing the system will turn to Fahrenheit and pressing the system will turn to Celsius. Default unit is Celsius.

  • Press  to confirm.
  • The 2nd parameter, d1 (Duration of massage) will be shown in the display. 
  • Press  to confirm.

Pressing  the duration of the massage can be increased or decreased. Default value is 10 minutes. The measurement unit is the minute.

  • Press  to confirm.
  • The 3rd parameter, d2 (Inhibition time) will be shown in the display. Controls how long the button that activates the pump is idle after finishing the massage cycle. 

Pressing   you can choose the massage inhibition time. The default value is 00 seconds. The measurement unit is the second.

  • Press   to confirm.
  • Press  or  or wait 10 seconds to exit the System Setup Menu.

General Parameter Configuration



Parameter


Description


Interval

Default value

Involved Function
UnTemperature unitsºC – ºFºCTemperature
d1Massage duration time 00-99(minutes)10 minutesWater/Air massage
d2Massage inhibition time 00-99 (seconds)00 secondsWater/Air massage
rnNr refill0-2 (s)0Ev load
d3Refill duration time00 – 99 (m)0Ev load

LIGHT CONTROL

Light is controlled by the LIGHT  button and/or the spa push button (optional).