Problems | Reasons | Solutions |
Insufficient flow of filtered water. | Filter is blocked by dirt. | Wash the filter. |
The massage pump of the Jets does not work. Spa does not work. | The cable of the digital control panel is disconnected from the board. No electrical supply. Differential is disconnected. | Connect the cable to the board. Check that the pump is connected to the electric control panel. Connect the differential |
The massage pump of the air Blower does not work. | The cable of the digital control panel is disconnected from the board. No electrical supply. The pump has disconnected owing to overheating. | Connect the cable to the board. Check that the pump is connected to the electric control panel. Let it cool for about 3 hours and then start-up the pump again. |
Water leaks out through the Venturi. | Jets are closed. Jets are not properly installed. The outer trim of the jet turns a quarter to open and close the water flow. If this trim makes a complete turn, it is not properly installed, and the jet will have to be removed and then placed correctly. | Open the jet. Remove the jet. Pull the outer trim about 2 cm. Unscrew the jet turning anticlockwise. Once it has been dismantled, replace the jet, by screwing in a clockwise direction. Press the outer trim back into place. |
Limited airflow in the Jets | Venturis are closed. | Open the Venturis. |
Reduced airflow. | Starter brushes of the motor are worn. | Change the pump. |
The water does not reach the required temperature. | Probe is damaged. Check programmed temperature. | Replace the temperature probe. Program the temperature. |
NOTE: In section 7. Error codes, you can find the diagnosis messages meaning to solve possible breakdowns.